array(15) { ["_edit_lock"]=> array(1) { [0]=> string(12) "1695120053:6" } ["_edit_last"]=> array(1) { [0]=> string(1) "6" } ["_yoast_wpseo_content_score"]=> array(1) { [0]=> string(2) "90" } ["_yoast_wpseo_estimated-reading-time-minutes"]=> array(1) { [0]=> string(1) "6" } ["_editorskit_title_hidden"]=> array(1) { [0]=> string(0) "" } ["_editorskit_reading_time"]=> array(1) { [0]=> string(1) "2" } ["_editorskit_typography_data"]=> array(1) { [0]=> string(6) "a:0:{}" } ["_editorskit_blocks_typography"]=> array(1) { [0]=> string(0) "" } ["redirect"]=> array(1) { [0]=> string(0) "" } ["_redirect"]=> array(1) { [0]=> string(19) "field_60ec1f44cda0a" } ["region"]=> array(1) { [0]=> string(0) "" } ["_region"]=> array(1) { [0]=> string(19) "field_6193c32031a77" } ["source"]=> array(1) { [0]=> string(14) "Nordic Markets" } ["_yoast_wpseo_wordproof_timestamp"]=> array(1) { [0]=> string(0) "" } ["footnotes"]=> array(1) { [0]=> string(0) "" } }

Cleaning indicators

Cleaning indicators are used daily to test the effectiveness of the cleaning and the disinfection in washer-disinfectors used for cleaning standard instruments and instruments for minimally invasive surgery. It is the critical parameters: time, temperature, water pressure and concentration of the detergent that are monitored. Cleaning indicators

Product description

A material consisting of artificial blood in accordance with ISO 15883 is applied to the cleaning indicator. After a cleaning cycle, the result is read manually using the included reading card. The results can be recorded on a documentation sheet on an ongoing basis.

The use of indicators is intended for everyone who needs to test cleaning processes such as hospitals, the pharmaceutical industry, the primary sector, dental surgeries and the food industry.

Multi check

Time, Temperature, water presure and detergent concentration is measured with this indicator in just one go

ISO compliant

The cleaning indicator is ISO 15882 compliant

Daily safety

Use the indicator on a daily basis to make sure your washer-disincector works as intended – For your daily safety

Easy interpretation

After the cleaning cycle it is easy to do the visual inspection based on the reading card.

How to use

It is recommended that the efficacy of the cleaning process is tested for each operating cycle in order to minimise the risk of infection. This is done by placing a cleaning indicator in one of the three types of cleaning simulators – process challenge device (PCD), which simulates the penetration requirements for either hollow instruments, e.g. minimally invasive surgical (MIS) devices, equipment with small apertures or large porous loads.

Depending on the chosen PCD, this must be positioned in a representative place in the washer-disinfector or connected to a representative cleaning nozzle.

After the cleaning cycle has finished, the cleaning indicator is removed and inspected visually to ensure that there is no trace of the material on the indicator. 

Product range

The indicators are supplied in packs of 50.

Article numberProduct
8664450-pack of cleaning indicators
866481 PCD – metal box (cleaning simulator for surgical instruments)
866465 PCD – tube (cleaning simulator for MIS instruments)
866491 PCD (PP) box – yellow (cleaning simulator for surgical instruments)
866505 PCD (PP) box – blue (cleaning simulator for narrow gaps)

Downloads

Please find the available downloads here.

IFU

Click on the link below to download the IFU.

Cleaning Indicators

Order Indicators Here

 With a biological and chemical indicators subscription, you:

  • Will receive certificates for approved test results
  • Can have the biological indicators cultured by our certified laboratory
  • Ensure safety for your patients and staff
  • Have a subscription scheme so you always have the indicators you need
  • Receive personal guidance and free biological indicators for re-testing test-positives
OBS: Subscriptions done on this page is only for Danish customers. If you are from outside Denmark please contact your sales rep. or write an email to info@ssidiagnostica.com

Simpler for the better

If you work within the field of microbiology, you might be familiar with Occam’s Razor. At SSI Diagnostica, we champion a slightly adapted version of this principle:
The simplest solution is usually the best one.

Other interesting content

Looking for something else? You might be interested in this as well.

Biological Indicator, for verification of your hygiene process

Biological indicators used to test steam sterilisation are microorganisms (spores of Geobacillus stearothermophilus, originally from ATCC 7953), prepared on filter paper as carrier material and packed in primary packaging consisting of transparent plastic film and paper which is steam-permeable.

Read more

Dual Indicator, Do your own verification of your sterilization process

Formaldehyde is a chemical gas, an alkylating agent that can kill microorganisms by destroying proteins and nucleic acids.  Biological indicators – formaldehyde.